Get the latest price? We will reply as soon as possible (within 12 hours)

DFYF-137Z Fully Automatic Cold Filter Plugging Point Tester

2026-05-29

Enhancing Low-Temperature Flow Performance Testing – Fully Automatic, High Precision, Dual-Station

In the testing of diesel, biodiesel, blended fuels, and petroleum products with strict low-temperature flow requirements, Cold Filter Plugging Point (CFPP) is a key indicator for evaluating fuel low-temperature flow performance and ensuring reliable engine start-up in cold conditions. The DFYF-137Z Fully Automatic CFPP Tester adopts industrial-grade PLC control and high-precision sensing technology to achieve fully automated CFPP determination. It is widely used in refineries, quality inspection centers, fuel storage and transportation companies, and third-party laboratories.



1. Wide Temperature Range with Precise Control

The instrument supports a temperature measurement range from -70°C to 0°C with a temperature control accuracy of ±0.1°C, meeting the CFPP analysis requirements of diesel and various low-temperature fuels under different environmental conditions.

2. Dual Cold Traps for Independent Operation – Double Efficiency

Equipped with 2 test cold traps that can operate independently, allowing simultaneous testing of two samples.

Each cold trap is fully equipped with an automatic detection and vacuum control system, operating without mutual interference – significantly improving laboratory testing efficiency.

3. Core Automation Functions

3.1 Automatic Pipette Filling Detection

Built-in sensors monitor the pipette filling process in real time, automatically drawing 20 mL ± 0.2 mL of sample (with a marking at 20 mL), ensuring consistent and accurate sample volume for each test.

3.2 Pipette Bottom Position Positioning

Another sensor automatically locates the bottom position of the pipette with a positioning accuracy of 85 mm ± 4 mm, providing an accurate reference for the filtration process.

3.3 Electronic Vacuum Regulator

Throughout the entire test, the vacuum regulator automatically maintains a stable negative pressure of 2 kPa ± 0.02 kPa, eliminating manual intervention and ensuring consistent filtration conditions.

3.4 High-Precision Time Measurement

The built-in time measurement device has an accuracy of 0.2 seconds, with an accuracy of 0.10% over 10 minutes, meeting the stringent time recording requirements of standard test methods.

4. Intelligent Control and Data Management

4.1 Industrial PLC Controller

The instrument adopts an industrial-grade PLC controller, offering stable operation and strong anti-interference capability, suitable for continuous operation in both laboratory and industrial environments.

4.2 7-Inch Color Touch Screen

Equipped with a 7-inch color touch screen featuring touch-button operation, the user-friendly interface makes parameter setting, test start-up, and result review quick and convenient.

4.3 Dual-Sample Independent Storage and Historical Data Query

Test results for 2 samples are stored independently without mixing.

Can store up to 10,000 sets of historical data, supporting conditional queries for quality traceability and data analysis.

4.4 Optional Micro Thermal Printer

After the test is completed, the instrument can automatically print results (printer optional), facilitating record keeping and archiving.

5. Structural Design Advantages

Feature

Description

Integrated structure

Compact design, small footprint – saves laboratory bench space

Dual independent cold traps

Two cold traps can operate simultaneously or separately – flexible and efficient

Fully enclosed refrigeration

Efficient fully enclosed compressor; single-stage auto-cascade or two-stage cascade – stable cooling

DFYF-137Z cold filter plugging point tester

6. Typical Applications

Refinery quality control – Routine CFPP testing of diesel, biodiesel, and blended fuels

Aviation fuel testing – Low-temperature flow performance evaluation of aviation kerosene

Fuel storage and transportation companies – Fuel supply quality control in low-temperature winter regions

Third-party testing agencies – Standard CFPP analysis of batch samples

Research and education – Low-temperature flow performance research and method development

7. Key Advantages at a Glance

Feature

Traditional Manual/Semi-Automatic CFPP Tester

DFYF-137Z Fully Automatic

Operation

Manual observation, manual recording

Fully automatic + touch screen control

Sample stations

Single station

Dual stations, independent operation

Vacuum control

Manual adjustment

Electronic automatic constant pressure, ±0.02 kPa

Data storage

None or limited

10,000 sets, searchable

Result printing

Handwritten

Automatic printing (optional)

Controller

Relay / microcontroller

Industrial PLC, stable and reliable

8. Service and Support

We provide full technical support – from installation and commissioning to operator training and after-sales maintenance. The DFYF-137Z, with its fully automatic operation, high precision, and dual-station design, is an ideal choice for your fuel low-temperature flow performance testing needs.

 DFYF-137Z CFPP analyzer




About Us

With nearly 40 years of specialized experience, Dalian Analysis Instrument Factory is a leading manufacturer of petroleum product testing instruments. We are ISO 9001 (2000) certified, ensuring reliable quality assurance in design, production, and after-sales service.

Our product line covers more than 100 varieties, including analyzers for gasoline, kerosene, diesel, lubricating oils, greases, and general laboratory equipment.




Contact Us

For standard models or customized solutions – we are here to help you improve your fuel low-temperature flow performance testing capabilities.

Sales Email: [lovecarlos2000@gmail.com]

24-Hour Hotline: +86 15941156556



ASTM D6371 analyzer